Force WebSQL to be enabled (obsolete)
Verified with Microsoft Edge 152.0.4191.53 — updated on July 10, 2026
Supported on: Microsoft Edge version 107-123, Windows 7 or later
Path in the GPO console
Computer Configuration\Administrative Templates\Microsoft Edge User Configuration\Administrative Templates\Microsoft Edge Description
OBSOLETE: This policy is obsolete and doesn't work after Microsoft Edge 123. This policy was removed in Microsoft Edge 124 and is ignored if set. WebSQL is on by default as of Microsoft Edge version 101, but can be disabled via a Microsoft Edge flag. If you enable this policy, WebSQL cannot be disabled. If you disable or don't configure this policy, WebSQL can be disabled.
Registry
Software\Policies\Microsoft\Edge Software\Policies\Microsoft\Edge Value name: WebSQLAccess
Enabled: WebSQLAccess = 1
Disabled: WebSQLAccess = 0
Export Builder
BETAConfigure the state, scope and options, then generate .reg, PowerShell, Intune and SCCM outputs — or add the setting to a multi-setting collection.
These exports write the registry — this is not a managed GPO. ⓘ
Applying both scopes creates an ambiguous configuration (computer takes precedence over user). Only do this intentionally.
.reg file
Windows Registry Editor Version 5.00
; Exported from gporais.com
; Policy: Force WebSQL to be enabled (obsolete)
; State: Enabled
; Scope: Computer (HKLM)
; Supported on: Microsoft Edge version 107-123, Windows 7 or later
[HKEY_LOCAL_MACHINE\Software\Policies\Microsoft\Edge]
"WebSQLAccess"=dword:00000001 More formats (PowerShell, Intune, SCCM)
PowerShell
# Exported from gporais.com
# Policy: Force WebSQL to be enabled (obsolete)
# State: Enabled
# Scope: Computer (HKLM)
# Supported on: Microsoft Edge version 107-123, Windows 7 or later
$path = 'HKLM:\Software\Policies\Microsoft\Edge'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'WebSQLAccess' -Value 1 -Type DWord Intune XML
No direct Policy CSP / OMA-URI mapping for this policy. Use the Intune Remediation tab, or ingest the ADMX in Intune. Intune Remediation
# === Detection script ===
# Exported from gporais.com
# Policy: Force WebSQL to be enabled (obsolete)
# State: Enabled
# Scope: Computer (HKLM)
# Supported on: Microsoft Edge version 107-123, Windows 7 or later
function Test-RegistryValue {
param(
[Parameter(Mandatory = $true)][string]$Path,
[Parameter(Mandatory = $true)][string]$Name,
[object]$Expected,
[ValidateSet('String', 'DWord', 'MultiString')][string]$Kind = 'String',
[switch]$Absent
)
try {
$item = Get-ItemProperty -LiteralPath $Path -Name $Name -ErrorAction Stop
} catch {
return $Absent.IsPresent
}
if ($Absent.IsPresent) { return $false }
$actual = $item.$Name
if ($Kind -eq 'DWord') { return ([int64]$actual) -eq ([int64]$Expected) }
if ($Kind -eq 'MultiString') {
$actualValues = @($actual)
$expectedValues = @($Expected)
if ($actualValues.Count -ne $expectedValues.Count) { return $false }
for ($i = 0; $i -lt $expectedValues.Count; $i++) {
if ([string]$actualValues[$i] -ne [string]$expectedValues[$i]) { return $false }
}
return $true
}
return [string]$actual -eq [string]$Expected
}
$checks = @(
(Test-RegistryValue -Path 'HKLM:\Software\Policies\Microsoft\Edge' -Name 'WebSQLAccess' -Expected 1 -Kind DWord)
)
if ($checks -notcontains $false) {
Write-Output 'Compliant'
exit 0
}
Write-Output 'Non-compliant'
exit 1
# === Remediation script ===
# Exported from gporais.com
# Policy: Force WebSQL to be enabled (obsolete)
# State: Enabled
# Scope: Computer (HKLM)
# Supported on: Microsoft Edge version 107-123, Windows 7 or later
$path = 'HKLM:\Software\Policies\Microsoft\Edge'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'WebSQLAccess' -Value 1 -Type DWord SCCM scripts
# Exported from gporais.com
# Policy: Force WebSQL to be enabled (obsolete)
# State: Enabled
# Scope: Computer (HKLM)
# Supported on: Microsoft Edge version 107-123, Windows 7 or later
# SCCM Configuration Item guidance:
# Create a Configuration Item of type "Setting: Script".
# Discovery script: use the Detection script below.
# Remediation script: use the Remediation script below.
# Compliance rule: the Discovery script output equals 'Compliant'.
# === Detection script ===
# Exported from gporais.com
# Policy: Force WebSQL to be enabled (obsolete)
# State: Enabled
# Scope: Computer (HKLM)
# Supported on: Microsoft Edge version 107-123, Windows 7 or later
function Test-RegistryValue {
param(
[Parameter(Mandatory = $true)][string]$Path,
[Parameter(Mandatory = $true)][string]$Name,
[object]$Expected,
[ValidateSet('String', 'DWord', 'MultiString')][string]$Kind = 'String',
[switch]$Absent
)
try {
$item = Get-ItemProperty -LiteralPath $Path -Name $Name -ErrorAction Stop
} catch {
return $Absent.IsPresent
}
if ($Absent.IsPresent) { return $false }
$actual = $item.$Name
if ($Kind -eq 'DWord') { return ([int64]$actual) -eq ([int64]$Expected) }
if ($Kind -eq 'MultiString') {
$actualValues = @($actual)
$expectedValues = @($Expected)
if ($actualValues.Count -ne $expectedValues.Count) { return $false }
for ($i = 0; $i -lt $expectedValues.Count; $i++) {
if ([string]$actualValues[$i] -ne [string]$expectedValues[$i]) { return $false }
}
return $true
}
return [string]$actual -eq [string]$Expected
}
$checks = @(
(Test-RegistryValue -Path 'HKLM:\Software\Policies\Microsoft\Edge' -Name 'WebSQLAccess' -Expected 1 -Kind DWord)
)
if ($checks -notcontains $false) {
Write-Output 'Compliant'
exit 0
}
Write-Output 'Non-compliant'
exit 1
# === Remediation script ===
# Exported from gporais.com
# Policy: Force WebSQL to be enabled (obsolete)
# State: Enabled
# Scope: Computer (HKLM)
# Supported on: Microsoft Edge version 107-123, Windows 7 or later
$path = 'HKLM:\Software\Policies\Microsoft\Edge'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'WebSQLAccess' -Value 1 -Type DWord Building a multi-setting collection? Add this setting and generate combined .reg / PowerShell / GPO scripts.