Send additional data when on battery power
Verified with Windows 11 25H2 — updated on July 30, 2026
Supported on: At least Windows Server 2012, Windows 8 or Windows RT
Path in the GPO console
User Configuration\Administrative Templates\Windows Components\Windows Error Reporting Description
This policy setting determines whether Windows Error Reporting (WER) checks if the computer is running on battery power. By default, when a computer is running on battery power, WER only checks for solutions, but does not upload additional report data until the computer is connected to a more permanent power source. If you enable this policy setting, WER does not determine whether the computer is running on battery power, but checks for solutions and uploads report data normally. If you disable or do not configure this policy setting, WER checks for solutions while a computer is running on battery power, but does not upload report data until the computer is connected to a more permanent power source.
Registry
SOFTWARE\Policies\Microsoft\Windows\Windows Error Reporting Value name: BypassPowerThrottling
Enabled: BypassPowerThrottling = 1
Disabled: BypassPowerThrottling = 0
MDM / Intune (CSP)
./User/Vendor/MSFT/Policy/Config/ADMX_ErrorReporting/WerBypassPowerThrottling_1 Microsoft Learn documentation Mapping data: Microsoft Learn (CC BY 4.0)
Export Builder
BETAConfigure the state, scope and options, then generate .reg, PowerShell, Intune and SCCM outputs — or add the setting to a multi-setting collection.
These exports write the registry — this is not a managed GPO. ⓘ
.reg file
Windows Registry Editor Version 5.00
; Exported from gporais.com
; Policy: Send additional data when on battery power
; State: Enabled
; Supported on: At least Windows Server 2012, Windows 8 or Windows RT
[HKEY_CURRENT_USER\SOFTWARE\Policies\Microsoft\Windows\Windows Error Reporting]
"BypassPowerThrottling"=dword:00000001 More formats (PowerShell, Intune, SCCM)
PowerShell
# Exported from gporais.com
# Policy: Send additional data when on battery power
# State: Enabled
# Supported on: At least Windows Server 2012, Windows 8 or Windows RT
# Warning: In SYSTEM context (the Intune default), HKCU targets the SYSTEM profile. Run this script using the logged-on credentials.
$path = 'HKCU:\SOFTWARE\Policies\Microsoft\Windows\Windows Error Reporting'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'BypassPowerThrottling' -Value 1 -Type DWord Intune XML
OMA-URI: ./User/Vendor/MSFT/Policy/Config/ADMX_ErrorReporting/WerBypassPowerThrottling_1
Data type: String
Value:
<enabled/> Intune Remediation
# === Detection script ===
# Exported from gporais.com
# Policy: Send additional data when on battery power
# State: Enabled
# Supported on: At least Windows Server 2012, Windows 8 or Windows RT
# Warning: In SYSTEM context (the Intune default), HKCU targets the SYSTEM profile. Run this script using the logged-on credentials.
function Test-RegistryValue {
param(
[Parameter(Mandatory = $true)][string]$Path,
[Parameter(Mandatory = $true)][string]$Name,
[object]$Expected,
[ValidateSet('String', 'DWord', 'MultiString')][string]$Kind = 'String',
[switch]$Absent
)
try {
$item = Get-ItemProperty -LiteralPath $Path -Name $Name -ErrorAction Stop
} catch {
return $Absent.IsPresent
}
if ($Absent.IsPresent) { return $false }
$actual = $item.$Name
if ($Kind -eq 'DWord') { return ([int64]$actual) -eq ([int64]$Expected) }
if ($Kind -eq 'MultiString') {
$actualValues = @($actual)
$expectedValues = @($Expected)
if ($actualValues.Count -ne $expectedValues.Count) { return $false }
for ($i = 0; $i -lt $expectedValues.Count; $i++) {
if ([string]$actualValues[$i] -ne [string]$expectedValues[$i]) { return $false }
}
return $true
}
return [string]$actual -eq [string]$Expected
}
$checks = @(
(Test-RegistryValue -Path 'HKCU:\SOFTWARE\Policies\Microsoft\Windows\Windows Error Reporting' -Name 'BypassPowerThrottling' -Expected 1 -Kind DWord)
)
if ($checks -notcontains $false) {
Write-Output 'Compliant'
exit 0
}
Write-Output 'Non-compliant'
exit 1
# === Remediation script ===
# Exported from gporais.com
# Policy: Send additional data when on battery power
# State: Enabled
# Supported on: At least Windows Server 2012, Windows 8 or Windows RT
# Warning: In SYSTEM context (the Intune default), HKCU targets the SYSTEM profile. Run this script using the logged-on credentials.
$path = 'HKCU:\SOFTWARE\Policies\Microsoft\Windows\Windows Error Reporting'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'BypassPowerThrottling' -Value 1 -Type DWord SCCM scripts
# Exported from gporais.com
# Policy: Send additional data when on battery power
# State: Enabled
# Supported on: At least Windows Server 2012, Windows 8 or Windows RT
# SCCM Configuration Item guidance:
# Create a Configuration Item of type "Setting: Script".
# Discovery script: use the Detection script below.
# Remediation script: use the Remediation script below.
# Compliance rule: the Discovery script output equals 'Compliant'.
# === Detection script ===
# Exported from gporais.com
# Policy: Send additional data when on battery power
# State: Enabled
# Supported on: At least Windows Server 2012, Windows 8 or Windows RT
# Warning: In SYSTEM context (the Intune default), HKCU targets the SYSTEM profile. Run this script using the logged-on credentials.
function Test-RegistryValue {
param(
[Parameter(Mandatory = $true)][string]$Path,
[Parameter(Mandatory = $true)][string]$Name,
[object]$Expected,
[ValidateSet('String', 'DWord', 'MultiString')][string]$Kind = 'String',
[switch]$Absent
)
try {
$item = Get-ItemProperty -LiteralPath $Path -Name $Name -ErrorAction Stop
} catch {
return $Absent.IsPresent
}
if ($Absent.IsPresent) { return $false }
$actual = $item.$Name
if ($Kind -eq 'DWord') { return ([int64]$actual) -eq ([int64]$Expected) }
if ($Kind -eq 'MultiString') {
$actualValues = @($actual)
$expectedValues = @($Expected)
if ($actualValues.Count -ne $expectedValues.Count) { return $false }
for ($i = 0; $i -lt $expectedValues.Count; $i++) {
if ([string]$actualValues[$i] -ne [string]$expectedValues[$i]) { return $false }
}
return $true
}
return [string]$actual -eq [string]$Expected
}
$checks = @(
(Test-RegistryValue -Path 'HKCU:\SOFTWARE\Policies\Microsoft\Windows\Windows Error Reporting' -Name 'BypassPowerThrottling' -Expected 1 -Kind DWord)
)
if ($checks -notcontains $false) {
Write-Output 'Compliant'
exit 0
}
Write-Output 'Non-compliant'
exit 1
# === Remediation script ===
# Exported from gporais.com
# Policy: Send additional data when on battery power
# State: Enabled
# Supported on: At least Windows Server 2012, Windows 8 or Windows RT
# Warning: In SYSTEM context (the Intune default), HKCU targets the SYSTEM profile. Run this script using the logged-on credentials.
$path = 'HKCU:\SOFTWARE\Policies\Microsoft\Windows\Windows Error Reporting'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'BypassPowerThrottling' -Value 1 -Type DWord Building a multi-setting collection? Add this setting and generate combined .reg / PowerShell / GPO scripts.