Critical battery notification level
Verified with Windows 11 25H2 — updated on July 30, 2026
Supported on: At least Windows Vista
Path in the GPO console
Computer Configuration\Administrative Templates\System\Power Management\Notification Settings Description
This policy setting specifies the percentage of battery capacity remaining that triggers the critical battery notification action. If you enable this policy setting, you must enter a numeric value (percentage) to set the battery level that triggers the critical notification. To set the action that is triggered, see the "Critical Battery Notification Action" policy setting. If you disable this policy setting or do not configure it, users control this setting.
Registry
Software\Policies\Microsoft\Power\PowerSettings\9A66D8D7-4FF7-4EF9-B5A2-5A326CA2A469 MDM / Intune (CSP)
./Device/Vendor/MSFT/Policy/Config/ADMX_Power/DCBatteryDischargeLevel0_2 Microsoft Learn documentation Mapping data: Microsoft Learn (CC BY 4.0)
Export Builder
BETAConfigure the state, scope and options, then generate .reg, PowerShell, Intune and SCCM outputs — or add the setting to a multi-setting collection.
These exports write the registry — this is not a managed GPO. ⓘ
.reg file
Windows Registry Editor Version 5.00
; Exported from gporais.com
; Policy: Critical battery notification level
; State: Enabled
; Supported on: At least Windows Vista
[HKEY_LOCAL_MACHINE\Software\Policies\Microsoft\Power\PowerSettings\9A66D8D7-4FF7-4EF9-B5A2-5A326CA2A469]
"DCSettingIndex"=dword:00000000 More formats (PowerShell, Intune, SCCM)
PowerShell
# Exported from gporais.com
# Policy: Critical battery notification level
# State: Enabled
# Supported on: At least Windows Vista
$path = 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings\9A66D8D7-4FF7-4EF9-B5A2-5A326CA2A469'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'DCSettingIndex' -Value 0 -Type DWord Intune XML
OMA-URI: ./Device/Vendor/MSFT/Policy/Config/ADMX_Power/DCBatteryDischargeLevel0_2
Data type: String
Value:
<enabled/>
<data id="EnterDCBatteryDischargeLevel0" value="0"/> Intune Remediation
# === Detection script ===
# Exported from gporais.com
# Policy: Critical battery notification level
# State: Enabled
# Supported on: At least Windows Vista
function Test-RegistryValue {
param(
[Parameter(Mandatory = $true)][string]$Path,
[Parameter(Mandatory = $true)][string]$Name,
[object]$Expected,
[ValidateSet('String', 'DWord', 'MultiString')][string]$Kind = 'String',
[switch]$Absent
)
try {
$item = Get-ItemProperty -LiteralPath $Path -Name $Name -ErrorAction Stop
} catch {
return $Absent.IsPresent
}
if ($Absent.IsPresent) { return $false }
$actual = $item.$Name
if ($Kind -eq 'DWord') { return ([int64]$actual) -eq ([int64]$Expected) }
if ($Kind -eq 'MultiString') {
$actualValues = @($actual)
$expectedValues = @($Expected)
if ($actualValues.Count -ne $expectedValues.Count) { return $false }
for ($i = 0; $i -lt $expectedValues.Count; $i++) {
if ([string]$actualValues[$i] -ne [string]$expectedValues[$i]) { return $false }
}
return $true
}
return [string]$actual -eq [string]$Expected
}
$checks = @(
(Test-RegistryValue -Path 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings\9A66D8D7-4FF7-4EF9-B5A2-5A326CA2A469' -Name 'DCSettingIndex' -Expected 0 -Kind DWord)
)
if ($checks -notcontains $false) {
Write-Output 'Compliant'
exit 0
}
Write-Output 'Non-compliant'
exit 1
# === Remediation script ===
# Exported from gporais.com
# Policy: Critical battery notification level
# State: Enabled
# Supported on: At least Windows Vista
$path = 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings\9A66D8D7-4FF7-4EF9-B5A2-5A326CA2A469'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'DCSettingIndex' -Value 0 -Type DWord SCCM scripts
# Exported from gporais.com
# Policy: Critical battery notification level
# State: Enabled
# Supported on: At least Windows Vista
# SCCM Configuration Item guidance:
# Create a Configuration Item of type "Setting: Script".
# Discovery script: use the Detection script below.
# Remediation script: use the Remediation script below.
# Compliance rule: the Discovery script output equals 'Compliant'.
# === Detection script ===
# Exported from gporais.com
# Policy: Critical battery notification level
# State: Enabled
# Supported on: At least Windows Vista
function Test-RegistryValue {
param(
[Parameter(Mandatory = $true)][string]$Path,
[Parameter(Mandatory = $true)][string]$Name,
[object]$Expected,
[ValidateSet('String', 'DWord', 'MultiString')][string]$Kind = 'String',
[switch]$Absent
)
try {
$item = Get-ItemProperty -LiteralPath $Path -Name $Name -ErrorAction Stop
} catch {
return $Absent.IsPresent
}
if ($Absent.IsPresent) { return $false }
$actual = $item.$Name
if ($Kind -eq 'DWord') { return ([int64]$actual) -eq ([int64]$Expected) }
if ($Kind -eq 'MultiString') {
$actualValues = @($actual)
$expectedValues = @($Expected)
if ($actualValues.Count -ne $expectedValues.Count) { return $false }
for ($i = 0; $i -lt $expectedValues.Count; $i++) {
if ([string]$actualValues[$i] -ne [string]$expectedValues[$i]) { return $false }
}
return $true
}
return [string]$actual -eq [string]$Expected
}
$checks = @(
(Test-RegistryValue -Path 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings\9A66D8D7-4FF7-4EF9-B5A2-5A326CA2A469' -Name 'DCSettingIndex' -Expected 0 -Kind DWord)
)
if ($checks -notcontains $false) {
Write-Output 'Compliant'
exit 0
}
Write-Output 'Non-compliant'
exit 1
# === Remediation script ===
# Exported from gporais.com
# Policy: Critical battery notification level
# State: Enabled
# Supported on: At least Windows Vista
$path = 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings\9A66D8D7-4FF7-4EF9-B5A2-5A326CA2A469'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'DCSettingIndex' -Value 0 -Type DWord Building a multi-setting collection? Add this setting and generate combined .reg / PowerShell / GPO scripts.