Specify a custom active power plan
Verified with Windows 11 26H2 — updated on July 30, 2026 Supported on: At least Windows Vista
Path in the GPO console
Computer Configuration\Administrative Templates\System\Power Management Registry
Software\Policies\Microsoft\Power\PowerSettings MDM / Intune (CSP)
./Device/Vendor/MSFT/Policy/Config/ADMX_Power/CustomActiveSchemeOverride_2 Microsoft Learn documentation Mapping data: Microsoft Learn (CC BY 4.0)
Description
This policy setting specifies the active power plan from a specified power plan’s GUID. The GUID for a custom power plan GUID can be retrieved by using powercfg, the power configuration command line tool. If you enable this policy setting, you must specify a power plan, specified as a GUID using the following format: XXXXXXXX-XXXX-XXXX-XXXX-XXXXXXXXXXXX (For example, 103eea6e-9fcd-4544-a713-c282d8e50083), indicating the power plan to be active. If you disable or do not configure this policy setting, users can see and change this setting.
Export Builder
BETAConfigure the state, scope and options, then generate .reg, PowerShell, Intune and SCCM outputs — or add the setting to a multi-setting collection.
These exports write the registry — this is not a managed GPO. ⓘ
.reg file
Windows Registry Editor Version 5.00
; Exported from gporais.com
; Policy: Specify a custom active power plan
; State: Enabled
; Supported on: At least Windows Vista
[HKEY_LOCAL_MACHINE\Software\Policies\Microsoft\Power\PowerSettings]
"ActivePowerScheme"="" More formats (PowerShell, Intune, SCCM)
PowerShell
# Exported from gporais.com
# Policy: Specify a custom active power plan
# State: Enabled
# Supported on: At least Windows Vista
$path = 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'ActivePowerScheme' -Value '' -Type String Intune XML
OMA-URI: ./Device/Vendor/MSFT/Policy/Config/ADMX_Power/CustomActiveSchemeOverride_2
Data type: String
Value:
<enabled/>
<data id="CustomActiveSchemeOverrideEnter" value=""/> Intune Remediation
# === Detection script ===
# Exported from gporais.com
# Policy: Specify a custom active power plan
# State: Enabled
# Supported on: At least Windows Vista
function Test-RegistryValue {
param(
[Parameter(Mandatory = $true)][string]$Path,
[Parameter(Mandatory = $true)][string]$Name,
[object]$Expected,
[ValidateSet('String', 'DWord', 'MultiString')][string]$Kind = 'String',
[switch]$Absent
)
try {
$item = Get-ItemProperty -LiteralPath $Path -Name $Name -ErrorAction Stop
} catch {
return $Absent.IsPresent
}
if ($Absent.IsPresent) { return $false }
$actual = $item.$Name
if ($Kind -eq 'DWord') { return ([int64]$actual) -eq ([int64]$Expected) }
if ($Kind -eq 'MultiString') {
$actualValues = @($actual)
$expectedValues = @($Expected)
if ($actualValues.Count -ne $expectedValues.Count) { return $false }
for ($i = 0; $i -lt $expectedValues.Count; $i++) {
if ([string]$actualValues[$i] -ne [string]$expectedValues[$i]) { return $false }
}
return $true
}
return [string]$actual -eq [string]$Expected
}
$checks = @(
(Test-RegistryValue -Path 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings' -Name 'ActivePowerScheme' -Expected '' -Kind String)
)
if ($checks -notcontains $false) {
Write-Output 'Compliant'
exit 0
}
Write-Output 'Non-compliant'
exit 1
# === Remediation script ===
# Exported from gporais.com
# Policy: Specify a custom active power plan
# State: Enabled
# Supported on: At least Windows Vista
$path = 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'ActivePowerScheme' -Value '' -Type String SCCM scripts
# Exported from gporais.com
# Policy: Specify a custom active power plan
# State: Enabled
# Supported on: At least Windows Vista
# SCCM Configuration Item guidance:
# Create a Configuration Item of type "Setting: Script".
# Discovery script: use the Detection script below.
# Remediation script: use the Remediation script below.
# Compliance rule: the Discovery script output equals 'Compliant'.
# === Detection script ===
# Exported from gporais.com
# Policy: Specify a custom active power plan
# State: Enabled
# Supported on: At least Windows Vista
function Test-RegistryValue {
param(
[Parameter(Mandatory = $true)][string]$Path,
[Parameter(Mandatory = $true)][string]$Name,
[object]$Expected,
[ValidateSet('String', 'DWord', 'MultiString')][string]$Kind = 'String',
[switch]$Absent
)
try {
$item = Get-ItemProperty -LiteralPath $Path -Name $Name -ErrorAction Stop
} catch {
return $Absent.IsPresent
}
if ($Absent.IsPresent) { return $false }
$actual = $item.$Name
if ($Kind -eq 'DWord') { return ([int64]$actual) -eq ([int64]$Expected) }
if ($Kind -eq 'MultiString') {
$actualValues = @($actual)
$expectedValues = @($Expected)
if ($actualValues.Count -ne $expectedValues.Count) { return $false }
for ($i = 0; $i -lt $expectedValues.Count; $i++) {
if ([string]$actualValues[$i] -ne [string]$expectedValues[$i]) { return $false }
}
return $true
}
return [string]$actual -eq [string]$Expected
}
$checks = @(
(Test-RegistryValue -Path 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings' -Name 'ActivePowerScheme' -Expected '' -Kind String)
)
if ($checks -notcontains $false) {
Write-Output 'Compliant'
exit 0
}
Write-Output 'Non-compliant'
exit 1
# === Remediation script ===
# Exported from gporais.com
# Policy: Specify a custom active power plan
# State: Enabled
# Supported on: At least Windows Vista
$path = 'HKLM:\Software\Policies\Microsoft\Power\PowerSettings'
New-Item -Path $path -Force | Out-Null
Set-ItemProperty -Path $path -Name 'ActivePowerScheme' -Value '' -Type String Building a multi-setting collection? Add this setting and generate combined .reg / PowerShell / GPO scripts.